Dell PowerEdge M520 사용자 설명서 - 페이지 5

{카테고리_이름} Dell PowerEdge M520에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge M520 26 페이지. Dell poweredge blade servers getting started guide
Dell PowerEdge M520에 대해서도 마찬가지입니다: 정보 업데이트 (38 페이지), 릴리스 정보 (27 페이지), 매뉴얼 (25 페이지), 사용자 설명서 (23 페이지), 중요 정보 매뉴얼 (35 페이지), 업데이트 매뉴얼 (32 페이지), 업데이트 매뉴얼 (28 페이지), 사용자 설명서 (22 페이지), 시작하기 매뉴얼 (12 페이지), 기술 매뉴얼 (46 페이지), 기술 매뉴얼 (45 페이지), 포트폴리오 매뉴얼 (27 페이지), 시작하기 매뉴얼 (14 페이지), 시작하기 매뉴얼 (12 페이지)

Dell PowerEdge M520 사용자 설명서
Dell 10Gb Ethernet Pass Through II
1
Overview
This manual explains the use of the embedded software management of the 10GbE PTM. It
explains how to connect to the 10GbE PTM and to the CMC, and how to update the module and
device firmware and software.
This manual covers the following topics:
• The rest of this section provides a high-level overview of the I/O Module structure and capabili-
ties
Section 2, "Connecting to the 10GbE PTM CLI," on page
10GbE PTM and issue CLI commands
Section 3, "Command Line Interface (CLI) Reference," on page 12
Section 4, "Operating Procedures," on page 19
required to achieve tasks such as software update
1.1

Port Groups

The 10GbE PTM has 16 front panel ports divided into two groups: A and B. Group A consists of
ports 1 through 8, providing service to blades 1 through 8, respectively; Group B consists of ports
9 through 16, providing service to blades 9 through 16, respectively.
The supported link protocol for all ports is 10GigE XAUI (KX4)
Figure 1 shows the front panel ports and their partitioning into Group A and Group B.
D
D
10 Gb Ethernet Pass Through II
D
1.2

Port Link State Reflection

The 10GbE PTM reflects the link state from the uplink to the downlink. When an uplink port con-
nected to a remote peer (e.g. an Ethernet switch) is disconnected, the respective server blade will
indicate link down event. When the uplink port is connected, the respective server blade will indi-
cate link up.
1.3

Link Protocol Mismatch Condition

A port may enter a link protocol mismatch condition. When in this condition, the port links (both
uplink and downlink) will remain inactive. Mismatch condition is indicated by the port LEDs.
Additional information about the mismatch condition is available via the CLI. Link protocol mis-
match would occur under the following conditions:
Figure 1: Front Panel Link Speed Port Groups
8, explains how to connect to the
documents the CLI
describes the detailed sequence of operations
Rev 1.00
5