Dell PowerEdge M710 업데이트 매뉴얼 - 페이지 3

{카테고리_이름} Dell PowerEdge M710에 대한 업데이트 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge M710 44 페이지. Dell poweredge blade servers getting started guide
Dell PowerEdge M710에 대해서도 마찬가지입니다: 정보 업데이트 (38 페이지), 업데이트 매뉴얼 (21 페이지), 업데이트 매뉴얼 (14 페이지), 설치 매뉴얼 (7 페이지), 업데이트 매뉴얼 (1 페이지), 시작하기 매뉴얼 (12 페이지), 시작하기 매뉴얼 (12 페이지), 기술 매뉴얼북 (31 페이지), 포트폴리오 매뉴얼 (27 페이지), 시작하기 매뉴얼 (14 페이지), 시작하기 매뉴얼 (12 페이지)

Dell PowerEdge M710 업데이트 매뉴얼

Memory Settings Screen

Option
System Memory Voltage
Memory Operating Voltage
(Auto Default)
Memory Operating Mode

Processor Settings Screen

Option
Intel(R) TXT (Disabled default) Enables/disables Trusted Execution Technology.
C1E (Enabled default)
Intel QPI Bandwidth Priority
(Compute default)
Adjacent Cache Line Prefetch
(Enabled default)
Hardware Prefetcher
(Enabled default)
DCU Streamer Prefetcher
(Enabled default)
Data Reuse
(Enabled default)
Description
Displays the system memory voltage.
Sets the system memory voltage selection.
Displays the type of memory operation if a valid memory
configuration is installed. When set to Optimizer mode, the
memory controllers run independent of each other for
improved memory performance. When set to Mirror mode,
memory mirroring is enabled. When set to Advanced ECC
Mode, two controllers are joined in 128-bit mode running
multi-bit advanced ECC. The Spare mode option is present
on systems with the Intel Xeon 5600 series processors only.
Description
To enable TXT, enable & activate VT & TPM with
pre-boot measurement.
Sets the processor performance state to minimum
when the system is idle.
Sets the bandwidth priority to compute or I/O.
Recommended for HPC applications.
Enables high utilization of sequential memory access.
NOTE:
Disable this option for applications that require
high utilization of random memory access.
Enables or disables the hardware prefetcher.
Enables Data Cache Unit streamer prefetcher.
Recommended for HPC applications.
Enables or disables data reuse. Recommended
for HPC applications.