Table 1. VEP4600 LED behavior (continued)
LED
LOCATOR LED/System Beacon
Temperature status LED
RJ-45 Ethernet link LED
RJ-45 Ethernet Activity LED
Table 2. System management Ethernet port LEDs
LED
Link LED
Activity LED
Table 3. SFP+ port LEDs
LED
Link/Activity LED
Expansion card LED behavior
Both system and temperature LEDs are dual-color, green and amber. There are two LEDs on the rNDC front panel:
1. System LED
2. Temperature LED
NOTE:
rNDC port LED behavior can be found in their respective datasheets.
10
VEP4600 platform
Description
● Flashing yellow—PSU warning event; power continues to
operate
● Off—Locator function disabled
● Flashing blue with 1 sec on and 1 sec off – Locator
function enabled
● Flashing blue with 2 sec on and 1 sec off – system in
standby
● Off—system off or in standby
● Solid green—temperature is normal
● Solid yellow—temperature is at the limit
● Flashing yellow—temperature is over the limit
● Off—No link
● Solid green—Link operating at a maximum speed,
autonegotiated/forced or 1G
● Solid yellow—Link operating at a lower speed,
autonegotiated/forced or 10/100M
● Off—No activity
● Flashing green—Port activity
Description
● Off—No link
● Solid green—Link operating at a maximum speed,
autonegotiated/forced or 1G
● Solid yellow—Link operating at a lower speed,
autonegotiated/forced or 10/100M
● Off—No activity
● Flashing green—Port activity
Description
● Off—No link
● Solid green—Link operating at maximum speed, 10G
● Solid yellow—Link operating at a lower speed, 1G
● Flashing green—port activity for 10G