the user to insert the resource CD. This will restart the system and the diagnostics will run from the 
resource CD. 
The PSA runs a low‐level check on the following hardware devices: 
System board 
Keyboard controller 
Hard drive controller 
LCD 
Memory 
If a test fails, the PSA issues a beep code and an on‐screen error code or both. Error codes can be looked 
up in the Quick View diagnostic accompaniment, and must be referenced in the online service request. 
The following is a sample list of PSA error codes: 
Error Code 
Error Message 
1000‐0111 
(Name of Exception) exception occurred at selector XXh offset XXh. 
1000‐0122 
Memory test initialization failure. 
10000‐0123 
Memory integration test failed. 
1000‐0141 
No drive detected. 
1000‐0142 
Drive Self Test failed. Status byte = XXh. 
1000‐0143 
Drive Smart read command failed 
1000‐0144 
No support for Drive Self Test 
1000‐0145 
Timeout waiting for Drive Self Test to complete. 
1000‐0146 
DST Log contains previous error(s) 
 
 
PSA+ Diagnostics 
PSA+ Diagnostics is a newer version of the PSA Diagnostics utility. 
It is not available on all systems due to space limitations on the BIOS chip. 
Systems that do not have enough space on the chip will use the standard PSA Diagnostics. 
Aside from changes in the look and feel, there are some other differences between the PSA+ and 
the original PSA Diagnostics: 
o Version Numbering – PSA+ Diagnostics has version numbers starting with 4, as in: 4xxx. 
The standard PSA Diagnostics has version numbers starting with 3, as in 3xxx. 
o Error Numbering – PSA+ Diagnostics has error codes starting with a 2, as in: 2000‐xxxx. 
The original version has error messages starting with 1, as in 1000‐xxxx. 
o Initial Touchpad Check – PSA+ Diagnostics incorporates a touchpad check when 
launched, whereas the standard PSA Diagnostics version does not. 
o MpMemory Algorithms – One of the most important feature enhancements for the 
PSA+ Diagnostics is the inclusion of MpMemory algorithms for enhanced testing of 
system memory. These algorithms are not present in the standard version. The 