The dimensions data for the Auxiliary Cooling Module is shown in Figure 1.
Dimensions,
Inches
H
W
25-7/8
36
Type
CFM
Swept
1,800
Figure 1. Auxiliary Cooling Module Dimensions and Data
ACM-407CP-IM (11/12)
Connections
Tube, OD,
inches
D
Inlet
Outlet
17-3/8
7/8
7/8
Fan
RPM
Dia., inches
810
20
Net
Sound,
Weight,
dB(A)
Lbs
52.0
95
Electrical
Power
Fan HP
230-1-60
1/6
Coil
Face Area,
Rows Fins/inch
2
15
Fan FLA
Min Voltage
1.0
207
Sq Ft
7.0