Dell PowerEdge R520 기술 매뉴얼 - 페이지 6
{카테고리_이름} Dell PowerEdge R520에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge R520 50 페이지. 2-socket, 2u rack server
Dell PowerEdge R520에 대해서도 마찬가지입니다: 매뉴얼 (11 페이지), 설치 매뉴얼 (8 페이지), 시작하기 매뉴얼 (9 페이지), 포트폴리오 매뉴얼 (27 페이지)
Table 1 summarizes the newest technologies used in the Dell PowerEdge R520 rack server.
New technologies
Intel Xeon processor
E5-2400 product family
Intel C600 series chipset
1600 MT/s DDR3
memory
Next generation PERC
options
PERC S110 software
RAID Solution
iDRAC7 with Lifecycle
Controller
DC power supply
Advanced power
management
Fresh Air cooling
Failsafe hypervisors
Fan fault tolerance
Detailed descriptions
This new family of Intel processors has embedded PCIe lanes for improved I/O
performance. See the Processor section for details.
The Intel Platform Controller Hub (PCH) chip is implemented on the R520 server.
Certain models of the E5-2400 series processors support 1600 MT/s memory. The
R520 supports two DIMMs per channel at 1600 MT/s with certain models. See the
Memory section for details.
The R520 supports the new PERC controller cards with improved functionality and
faster performance. See the Storage section for details.
This new software RAID solution supports RAID 0, 1, 5 and 10, and supports a
maximum of four hot-plug SATA hard drives or SATA solid-state drives. See the
Storage section for details.
The new embedded system management solution for Dell servers features
hardware and firmware inventory and alerting, in-depth memory alerting, faster
performance, a dedicated gigabit port, and many more features. See the Dell
OpenManage systems management section for details.
A new 1100W DC power supply option is available for the R520. See the Power,
thermal, and acoustics section for details.
The R520 supports advanced power monitoring and power capping tools that can
help manage power consumption. See the Power, thermal, and acoustics section
for details.
Dell has tested and validated an integrated data center solution that enables you
to operate at higher temperatures or even chiller-less. See the Power, thermal, and
acoustics section for details.
The internal dual SD module is a modular fail-safe design that is dedicated for an
embedded ESX hypervisor or other embedded operating system. See the
Supported virtualization section.
Failure of one fan motor is tolerated with degradation in performance through
active throttling and increased fan speeds. The feature helps reduce downtime by
allowing you to schedule a fan replacement within 360 hours of a fan failure.