Dell PowerVault 211S 교체 지침 매뉴얼 - 페이지 13
{카테고리_이름} Dell PowerVault 211S에 대한 교체 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerVault 211S 14 페이지. Dell powervault 20xs storage systems enclosure services
expander module installation
Dell PowerVault 211S에 대해서도 마찬가지입니다: 랙 설치 매뉴얼 (26 페이지), 매뉴얼 (9 페이지), 업데이트 (4 페이지), 구성 (2 페이지), 설치 매뉴얼 (48 페이지)
Install the Hard-Disk Drives
NOTICE: Install the hard-disk drives in the same drive bays from
which they were removed.
NOTICE: Handle the hard-disk drives with care. The carriers provide
some protection, but the hard-disk drives can be damaged by rough
handling. When installing hard-disk drives, use gentle pressure to
slide them in the drive bays. Insert them slowly; never use force.
To install the hard-disk drives, perform the following steps:
1. Carefully slide the hard-disk drive into the bay (see Figure 13). When the
hard-disk drive is almost all the way into the bay, the carrier handle flips up.
Figure 13. Installing a SCSI Hard-Disk Drive (System Shown with a
Swing-out Lock Bar)
2. Close the handle to draw the drive carrier into the bay and lock the drive in
place.
3. Repeat steps 1 and 2 to install the remaining hard-disk drives.
4. For a storage system with a silver swing-out lock bar, raise the lock bar to
the lock position. The lock bar slips down into a detent. This holds the lock
bar in the lock position.
If the storage system is in a stand-alone configuration, swing the lock bar
to the left into the lock position. The lock bar slips to the right into a detent.
This holds the lock bar in the lock position.
For a storage system with a black, removable lock bar, place the left end of
the lock bar into its hole in the left side of the front panel. Then, align the
lock bar with the locking mechanism by the keylock (see Figure 14).
Dell PowerVault 2xxS Storage Systems SCSI Backplane Board Replacement Instructions