Dell PowerVault LTO-3-060 사용자 설명서 - 페이지 25

{카테고리_이름} Dell PowerVault LTO-3-060에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerVault LTO-3-060 37 페이지. Powervault tape systems
Dell PowerVault LTO-3-060에 대해서도 마찬가지입니다: 설정 (2 페이지), 핸드북 (28 페이지)

Dell PowerVault LTO-3-060 사용자 설명서
1. Ensure there is no cartridge in the drive.
Note:
If a cartridge is loaded in the drive, depression of the Unload button is interpreted as an unload request and the drive will ignore the second and third
depressions. The drive cannot be put into Service mode while a cartridge is loaded.
2. Press and hold the Unload button until the Ready LED begins flashing rapidly indicating Service Function 1 has been accessed. The status LEDs will be in one of
the following states.
LED icon
Key:
= OFF
= ON
= Flashing slowly
= Flashing rapidly
Important
The drive will timeout if the next step is not performed within 15 seconds.
3. Press the Unload button 4 times to access Service Function 5. The status LEDs will be in one of the following states.
LED icon
Key:
= OFF
= ON
= Flashing slowly
= Flashing rapidly
Service Function 1; no drive dump
in memory
Service Function 5
LED state
Service Function 1; drive dump in
RAM
LED state
Service Function 5; drive dump in
RAM
Service Function 1; drive dump in
flash memory
Service Function 5; drive dump in
flash memory