Dell PowerVault MD3420 소유자 매뉴얼 - 페이지 27

{카테고리_이름} Dell PowerVault MD3420에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerVault MD3420 47 페이지. Storage arrays
Dell PowerVault MD3420에 대해서도 마찬가지입니다: 시작하기 매뉴얼 (8 페이지), 배포 매뉴얼 (27 페이지)

Dell PowerVault MD3420 소유자 매뉴얼
7.
Turn on the array and the host server.

Power Supply/Cooling Fan Module

NOTE: Your storage array includes two integrated, hot-swappable power supply/cooling fan
modules.
The array supports two hot-swappable power supply/cooling fan modules. While the array can operate
temporarily with one module, both the modules must be present for proper system cooling.
CAUTION: A single power supply/cooling fan module can be removed from a powered-on array
for a maximum period of 5 minutes. Beyond that time, the array may automatically shut down to
prevent damage.

Removing a Power Supply/Cooling Fan Module

CAUTION: Many repairs may only be done by a certified service technician. You must only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: If you remove a fully functioning power supply/cooling fan module, the fan speed in the
remaining module increases significantly to provide adequate cooling. The fan speed decreases
gradually when a new power supply/cooling fan module is installed.
1.
Turn off the power supply/cooling fan module.
2.
Disconnect the power cable from the power source.
3.
Remove the straps that secure the power cable and disconnect the power cable from the power
supply/cooling fan module.
WARNING: The power supply/cooling fan modules are heavy. Use both hands while
removing the module.
27