Back-Panel Connectors (Per RAID Controller
Module)
Management Ethernet connector
Power
AC power supply (per power supply)
Wattage
Heat dissipation (maximum)
NOTE: Heat dissipation is calculated
using the power supply wattage
rating. The heat dissipation values are
for the entire system which includes
chassis and two controllers.
Voltage
NOTE: This system is also designed to
be connected to IT power systems
with a phase to phase voltage not
exceeding 230 V.
Battery
Environmental
NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
44
NOTE: For technical support use only.
One 100/1000 Mbps Ethernet connection for out-of-
band management of the enclosure (MGMT)
600 W
100 W
100–220 V AC, (8.6 A-4.3 A)
6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery
Continuous operation: 10 °C to 35 °C (50 °F to 95 °F) at
20% to 80% relative humidity (RH), with 26 °C
maximum dew point. De-rate maximum allowable dry
bulb temperature at 1 °C/300 m (1 °F per 550 ft) above
900 m (2952.75 ft).
NOTE: For information on supported expanded
operating temperature range and configurations,
see the Owner's Manual at dell.com/
powervaultmanuals.
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20 °C per hour
10% to 80% (noncondensing) with maximum humidity
gradation of 10% per hour