Dell PowerVault MD3860i Series 소유자 매뉴얼 - 페이지 48
{카테고리_이름} Dell PowerVault MD3860i Series에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerVault MD3860i Series 50 페이지. Storage arrays
Back-Panel Connectors (Per RAID Controller
Module)
Serial connector (debug port)
Management Ethernet connector
iSCSI connectors
Power
AC power supply (per power supply)
Wattage
Heat dissipation (maximum)
NOTE: Heat dissipation is calculated
using the power supply wattage rating.
The heat dissipation values are for the
entire system which includes chassis and
two controllers.
Voltage
NOTE: This system is also designed to be
connected to IT power systems with a
phase to phase voltage not exceeding
230 V.
Battery
Environmental
NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.
Temperature
48
NOTE: SAS and iSCSI connections to the
same host is not supported.
Two SAS OUT ports, it is recommended that you
use the first port for expansion to an additional
PowerVault MD3060e expansion enclosure. Only
one expansion port is supported at any given time.
NOTE: SAS connectors are SFF-8644
compliant.
One 6-pin mini serial port
NOTE: For technical support use only.
One 100/1000 Mbps Ethernet connection for out-
of-band management of the enclosure and the
second Ethernet port is reserved.
Two 10 Gbps iSCSI IN connectors to connect
hosts
1755 W
5988 BTU/hr
220 V AC, autoranging, 50 Hz/60 Hz
6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery