Dell SC180 소유자 매뉴얼 - 페이지 32

{카테고리_이름} Dell SC180에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell SC180 37 페이지. Storage center
Dell SC180에 대해서도 마찬가지입니다: 소유자 매뉴얼 (39 페이지)

Dell SC180 소유자 매뉴얼

Troubleshooting SC180 Components

This section contains basic troubleshooting steps for components inside the SC180 expansion
enclosures.

Troubleshooting Fan Modules

Use these steps to troubleshoot fan modules.
1.
Check the status of the fan module using the Dell Storage Client.
2.
Determine the status of the fan module LEDs.
If the fan fault indicator is lit, the fan module has failed.
3.
Reseat the fan module by removing and reinstalling it.
NOTE: Allow several seconds for the expansion enclosure to recognize the fan module and
determine its status.

Troubleshooting PSUs

Use these steps to troubleshoot Power Supply Units (PSUs).
1.
Check the status of the PSU using the Dell Storage Client.
2.
Determine the status of the PSU LEDs.
If the PSU fault indicator is lit, the PSU has failed.
If the Power OK LED is not lit, check the power cord and power source into which the power
supply is plugged:
– Connect another device to the power source and check whether the device works.
– Connect the power cord to a different power source.
– Replace the power cord.
If the AC fault LED is lit, this PSU is not supplying power, though the other PSU may still be
supplying power.
3.
Reseat the PSU by removing and reinstalling it.
NOTE: Allow several seconds for the expansion enclosure to recognize the PSU and determine
its status.

Troubleshooting Disk Drives

Use these steps to troubleshoot disk drives in carriers (DDICs).
1.
Check the status of the disk drive using the Dell Storage Client.
2.
Determine the status of the DDIC LED.
If the DDIC fault LED is lit, the hard drive has failed.
32
Troubleshooting SC180 Components
3