Dell SCv2080 소유자 매뉴얼 - 페이지 26
{카테고리_이름} Dell SCv2080에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell SCv2080 45 페이지. Storage center
Dell SCv2080에 대해서도 마찬가지입니다: 소유자 매뉴얼 (49 페이지), 시작하기 매뉴얼 (24 페이지), 시작하기 매뉴얼 (23 페이지)
6.
Select the failed cooling fan. The location of the failed cooling fan module is displayed in the Fan
View tab.
Figure 16. Rear View of the Enclosure Showing the Failed the Cooling Fan Module
Replacing a Cooling Fan Module
Use this procedure to replace a failed cooling fan module.
Prerequisites
1.
Use SupportAssist to send diagnostic data to Dell Technical Support Services.
2.
Contact Dell Technical Support Services to let them know that you are performing a repair.
About this task
You can replace cooling fan modules one at a time without shutting down the storage system.
Steps
1.
Press the release tab and pull the fan module out of the chassis using the handle.
CAUTION: The fan modules are heavy. To avoid injury, use both hands while removing the
module.
26
Get other manuals https://www.bkmanuals.com
Replacing SCv2080 Components