Dell Storage Center SCv2000 소유자 매뉴얼 - 페이지 30
{카테고리_이름} Dell Storage Center SCv2000에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell Storage Center SCv2000 42 페이지. Storage center
Dell Storage Center SCv2000에 대해서도 마찬가지입니다: 시작하기 매뉴얼 (19 페이지), 시작하기 매뉴얼 (20 페이지)
•
Controlling access to hard drives
•
Communicating storage attributes and states to the storage system
NOTE: Do not return the storage controller battery with the failed storage controller. A new battery
is not included with a replacement storage controller.
Identify the Failed Storage Controller
To determine which storage controller failed, use the Dell Storage Client .
1.
Click the Hardware tab.
2.
In the Hardware tab navigation pane, select the Storage Center.
3.
In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed
storage controller.
Figure 23. Hardware Alert Identifying the Enclosure with the Failed Storage Controller
4.
In the Hardware tab navigation pane, expand the Enclosures entry.
5.
Click I/O Modules. The status of each storage controller is displayed in the I/O Modules tab.
6.
Select the failed storage controller to display its location in the IO Module View tab.
30
Replacing SCv2000/SCv2020 Components