Dell 4605M 펌웨어 업그레이드 지침 - 페이지 11
{카테고리_이름} Dell 4605M에 대한 펌웨어 업그레이드 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell 4605M 17 페이지. Emcnetworking switches
- 1. Table of Contents
- 2. Introduction
- 3. Global Support
- 4. Firmware Upgrade Overview
- 5. Firmware Downgrade Overview
- 6. How to Access Serial Console on Dell EMC Networking N1500 Series Switches
- 7. Upgrade Example of Dell EMC Networking N1500 Series Switches
- 8. Upgrade Stack of Dell EMC Networking N1500 Series Switches
- 9. Switch Recovery Procedure
- 10. Switch Recovery Example
- 11. End of Document
Upgrade Dell EMC Networking N1500 Series Switches
Upgrade Stack of Dell EMC Networking N1500 Series Switches
Note on "copy" command from steps 2,3 and 4 in switch upgrade above:
"copy" command will take longer to complete with a stack of switches. This is due to the master switch
copying the software to the member switches. The master switch will display the line "Distributing the
code to the members of the stack!" for several minutes until the copy is done.
"copy" command will copy the software to all the switches as "backup" image
console#show version
Machine Description............... Dell Networking Switch
System Model ID................... N1548P
Machine Type...................... Dell Networking N1548P
Serial Number..................... 15114M0002LF
Manufacturer...................... 0xbc00
Burned In MAC Address............. 001E.C9E5.BD0F
System Object ID.................. 1.3.6.1.4.1.674.10895.3066
SOC Version.......................
HW Version........................ 1
CPLD Version...................... 16
unit active
--- ----------- ----------- -------------- --------------
1
6.3.3.14
2
6.3.3.14
3
6.3.3.14
4
6.3.3.14
console# boot system backup
Activating image backup ..
console#show version
System Model ID................... N1548P
Machine Type...................... Dell Networking N1548P
Serial Number..................... 15114M0002LF
Manufacturer...................... 0xbc00
Burned In MAC Address............. 001E.C9E5.BD0F
System Object ID.................. 1.3.6.1.4.1.674.10895.3066
SOC Version.......................
HW Version........................ 1
CPLD Version...................... 16
unit active
--- ----------- ----------- -------------- --------------
1
6.3.3.14
2
6.3.3.14
3
6.3.3.14
4
6.3.3.14
console#reload
Management switch has unsaved changes.
Are you sure you want to continue? (y/n) y
Configuration Not Saved!
Are you sure you want to reload the stack? (y/n) y
After the stack of switches has finished rebooting, log in and verify that the firmware has been
updated to the
version using the show version command. A single switch will typically
6.5.2.9
reboot in around two minutes. A stack may take significantly longer to complete the upgrade
process.
BCM56150_A0
backup
current-active next-active
6.5.2.9
6.3.3.14
6.5.2.9
6.3.3.14
6.5.2.9
6.3.3.14
6.5.2.9
6.3.3.14
BCM56150_A0
backup
current-active next-active
6.5.2.9
6.3.3.14
6.5.2.9
6.3.3.14
6.5.2.9
6.3.3.14
6.5.2.9
6.3.3.14
6.3.3.14
6.3.3.14
6.3.3.14
6.3.3.14
6.5.2.9
6.5.2.9
6.5.2.9
6.5.2.9
Page 9