Dell EMC PowerEdge R640 매뉴얼 - 페이지 41
{카테고리_이름} Dell EMC PowerEdge R640에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell EMC PowerEdge R640 49 페이지. Metro node
Dell EMC PowerEdge R640에 대해서도 마찬가지입니다: 하드웨어 설치 매뉴얼 (2 페이지)
![Dell EMC PowerEdge R640 매뉴얼](/uploads/products/server2/3222201/3222201.jpg)
Topics:
•
Power supply specifications
•
Chassis dimensions
•
Environmental specifications
•
Video specifications
Power supply specifications
The PowerEdge R640 systems support up to two AC or DC power supply units (PSUs).
Table 21. PSU specifications
PSU
Class
495 W AC
Platinum
750 W AC
Platinum
750 W AC
Titanium
750 W Mixed
Platinum
Mode HVDC—
for China only
1100 W AC
Platinum
1100 W Mixed
Platinum
Mode HVDC—
for China and
Japan only
1600 W AC
Platinum
Table 22. PSU specifications
PSU
Class
750 W Mixed Mode HVDC
NA
—for China only
1100 W DC
NA
Appendix A. Additional specifications
Heat dissipation—
Frequency
maximum
1908 BTU/hr
50/60 Hz
2891 BTU/hr
2843 BTU/hr
2891 BTU/hr
4100 BTU/hr
4100 BTU/hr
6000 BTU/hr
Heat dissipation—
maximum
2891 BTU/hr
4416 BTU/hr
Voltage
Current
100–240 V AC, autoranging 6.5 A – 3 A
100–240 V AC, autoranging 10 A – 5 A
200–240 V AC,
5 A
autoranging
100–240 V AC, autoranging 10 A – 5 A
100–240 V AC, autoranging 12 A – 6.5 A
100–240 V AC, autoranging 12 A – 6.5 A
100–240 V AC, autoranging 10 A
Frequency
Voltage
50/60 Hz
240 V DC,
autoranging
–(48–60) V DC,
autoranging
Appendix A. Additional specifications
11
Current
4.5 A
32 A
41