Port Numbering Convention

Even-numbered ports are at the bottom of the I/O panel and for modules odd-numbered ports are at the top of the I/O
panel.
Figure 4. Port Numbering
The previous figure shows the fixed four 40GbE data ports (ports 48, 52, 56, and 60) and the four slots for pluggable
modules on the S5000 I/ O panel. You can also use the 40GbE ports in 4 × 10GbE mode.
The S5000 supports the following possible modules:
12-Port Ethernet Module (1G/10G speeds) (slot 0, 1, 2, or 3)
12-Port Fibre Channel Module (2G/4G/8G speeds) (slot 0)
The valid slot numbers are stack-unit numbers (from 0 to 11). The valid port numbers for each interface type are:
1GbE: Ports 0 to 47
10GbE: Ports 0 to 63
40GbE: Ports 48, 52, 56, and 60
Fibre Channel: Ports 0 to 11
Management: Port 0

System Status

You can view S5000 status information in several ways, including LEDs and through the CLI show commands and with
simple network management protocol (SNMP).
For more information about these options, refer to the
Guide for the S5000 Switch .
As shown in the following figure, the S5000 includes LED displays on the I/O and Utility side of the chassis. When the
S5000 powers up or reloads, the status LED on the power supplies are solid green.
The following table lists the LED definitions for the S5000 system.
FTOS Command Line Reference Guide and FTOS Configuration