To install the switch in a rack, complete the following steps:
1
Use the supplied screws to attach a mounting bracket to each side of the switch (see
Figure 1-7).
Figure 1-7. Brackets for Rack Installation
2
Install the cage nuts onto the mounting rails of your rack, if your rack requires them.
NOTE:
3
Position the switch in the rack and align the holes in the mounting bracket with the holes in
the rack.
4
Insert and tighten two screws appropriate for your rack through each of the mounting
brackets.
Installing the Switch on a Wall
To mount the switch on a wall, complete the following steps:
1
Ensure that the mounting point meets the following requirements:
•
The wall surface must be capable of supporting the switch.
•
Allow at least 5.1 cm (2 inches) on each side for proper ventilation and 12.7 cm (5 inches)
at the back for power cable clearance.
•
The location must not be located in direct sunlight.
•
The location must not be within 2 feet of any heating vents, nor should any area heating
vent point toward the unit.
•
The location must be ventilated to prevent heat buildup.
12
Introduction
Additional screws are provided for racks that have threaded mounting holes.