The following figure is representative of PowerConnect 5224.
Switch 5224: Re-Enabling a Shutdown Port
If security is enabled on a port and you set the intrusion action to Trap and
Shutdown, a security violation causes the port to be disabled. To re-enable a
shutdown port, follow these steps:
Click the Ports/Port Configuration page.
1
For the port that is disabled, click the check box in the Admin/Oper
2
column.
Click Apply Changes to enable the port.
3
Switch 5224: CLI Commands
The following table summarizes the equivalent CLI commands for items in
the Ports/Port Security pages.
Command
port security
Usage
Enables port security on an interface.
The no form command disables port security.