Dell POWERCONNECT 5524 시작하기 매뉴얼 - 페이지 8

{카테고리_이름} Dell POWERCONNECT 5524에 대한 시작하기 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell POWERCONNECT 5524 20 페이지. Powerconnect 5500 series
Dell POWERCONNECT 5524에 대해서도 마찬가지입니다: 릴리스 정보 (15 페이지)

Dell POWERCONNECT 5524 시작하기 매뉴얼
3 Repeat the process for the rack-mounting bracket on the other side of the
switch.
4 Insert the unit into the 48.26-cm (19-inch) rack, ensuring that the
rack-mounting holes on the switch line up to the mounting holes on the
rack.
5 Secure the unit to the rack with the rack screws (not provided). Fasten the
lower pair of screws before the upper pair of screws. Ensure that the
ventilation holes are not obstructed.

Installing on a Flat Surface

Install the switch on a flat surface if it is not installed on a rack. The surface
must be able to support the weight of the switch and the switch cables.
To install the switch on a flat surface:
1 Attach the self-adhesive rubber pads on each marked location on the
bottom of the chassis.
2 Set the switch on a flat surface, leaving 5.08 cm (2 inches) on each side
and 12.7 cm (5 inches) at the back.
3 Ensure that the switch has proper ventilation.

Connecting the Switch to Power Supplies

Each switch in the stack must be connected to an AC power supply.
The power connectors are positioned on the back panel. Connecting a
Redundant Power Supply (RPS) or Modular Power Supply (MPS) is optional,
but recommended. The RPS or MPS connector is on the back panel of the
switch. The RPS is used for non-PoE switches and MPS is used for PoE
switches.
Figure 1-2. Back-Panel Power Connector
8
Installation
RPS or MPS
A/C Power Supply