Dell PowerConnect M6220 펌웨어 업그레이드
Upgrading PowerConnect Switches from Version 2.x.x.x or 3.x.x.x or
4.x.x.x or 5.x.x.x to 5.1.9.3 Firmware

Stacking Notes

Regarding steps 3, 4 and 5 above:
The "copy" command will take longer to complete with a stack of switches. This is due to the master
switch copying the software to the member switches. The master switch will display the line "Distributing
the code to the members of the stack!" for several minutes until the copy is done.
The "copy" command will copy the software to the non-active image on all the switches.
Examples:
If all switches in the stack have image1 as active, then the downloaded software will go to image2 on all
switches and a single "boot system image2" command will select image2 for the next active image on all
switches in the stack.
console#show version
Image Descriptions
image1 : default image
image2 :
Images currently available on Flash
--------------------------------------------------------------------
unit
image1
--------------------------------------------------------------------
1
4.2.1.3
2
4.2.1.3
console# boot system image2
Activating image image2 ..
console#show version
Image Descriptions
image1 : default image
image2 :
Images currently available on Flash
--------------------------------------------------------------------
unit
image1
--------------------------------------------------------------------
1
4.2.1.3
2
4.2.1.3
console#update bootcode
Update bootcode and reset (Y/N)?y
Management switch has unsaved changes.
Are you sure you want to continue? (Y/N) y
Issuing boot code update command...
Validating boot code from image...CRC Valid.
If the switches in the stack have some image1 active and some image2 active members, then the
downloaded software will go to the non-active image on each switch and multiple "boot system <unit>
imageX" commands will be required to select the next active image on each switch in the stack.
image2
current-active
5.1.9.3
image1
5.1.9.3
image1
image2
current-active
5.1.9.3
image1
5.1.9.3
image1
Page 8
next-active
image1
image1
next-active
image2
image2