Dell PowerConnect M8024-F 구성 매뉴얼 - 페이지 12
{카테고리_이름} Dell PowerConnect M8024-F에 대한 구성 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerConnect M8024-F 21 페이지. For equallogic sans
3.5
Check current operational mode
Note: Before proceeding, the "System Operational Mode" must be set to "Normal". Some switches, such
as the M8024k, ship from the factory in simple mode.
console>enable
console#configure
console(config)#no mode simple
Switching modes will immediately clear the configuration.
to continue? (y/n) y
Switch has unsaved changes.
Are you sure you want to continue? (y/n) y
Note: The switch will reboot. If the switch reports "Normal mode already active", then you may proceed
to the next step without rebooting.
3.6
Disable DCB
Note: The PowerConnect M8024-k switches do not support Enhanced Transmission Selection (ETS),
therefore Data Center Bridging (DCB) must be manually disabled using the following steps. If you have
the M8024 switch, skip this section.
console>enable
console#configure
console(config)#no dcb enable
3.7
Configure out of band (OOB) management port
console(config)#interface out-of-band
console(config-if)#ip address ipaddress mask gateway
console(config-if)#exit
3.8
Configure login credentials
console(config)#line telnet
console(config-telnet)#login authentication default
console(config-telnet)#exit
12
SCG1008
PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs
Are you sure you want