Allied Telesis CONVERTEON AT-CM2K0S 설치 매뉴얼 - 페이지 2
{카테고리_이름} Allied Telesis CONVERTEON AT-CM2K0S에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Allied Telesis CONVERTEON AT-CM2K0S 3 페이지. Converteon series line card
Allied Telesis CONVERTEON AT-CM2K0S에 대해서도 마찬가지입니다: 데이터시트 (3 페이지), 데이터시트 (2 페이지)
LED
State
Description
Off
The port is not operating at 100 Mbps.*
* When the 1000M and 100M LEDs are both off, the port is operating at 10 Mbps.
DIP Switch Settings
The DIP switches as described in the following table allow you to set the operating mode
of the line card. For information about the operating modes as well as Smart MissingLink,
MissingLink, and OAM, refer to the relevant management software user's guide.
Operating Mode
DIP 1
Link Test (default)
OFF
OFF
Smart MissingLink (SML)
OFF
ON
MissingLink (ML)
OFF
OFF
OAM Bypass
ON
OFF
OAM Visible
ON
ON
"X" means that the DIP switch position can be ON or OFF.
Twisted Pair Port Pinouts
The pinouts for the RJ-45 twisted pair port are shown in the following illustration.
8
8
1
1
The following table lists the RJ-45 pin signals when a twisted pair port is operating in the
MDI or MDI-X mode.
MDI Mode
Pin
Signal
Pin
1
TX+
1
2
TX-
2
3
RX+
3
6
RX-
6
Warranty Information
The AT-CM2K0S line card has a limited warranty of five years. Go to
www.alliedtelesis.com/warranty for the specific terms and conditions of the warranty and
for warranty registration.
Specifications
Physical, Environmental, and Electrical Ratings
Dimensions (H x W x L)
(2.2 cm x 7.3 cm x 13.0 cm)
.78 in. x 2.89 in. x 5.1 in.
Operating Temperature
0° C to 40° C (32° F to 104° F)
Storage Temperature
-25° C to 70° C (-13° F to 158° F)
Operating Relative Humidity
5% to 90% (non-condensing)
Storage Relative Humidity
5% to 95% (non-condensing)
Operating Altitude Range
Up to 3,048 m (10,000 ft.)
Predicted MTBF (Telcordia SR332)
880,000 hours
Power Consumption
6.5 Watts maximum
Electrical Safety and Emissions Statements
This product meets the following standards when installed in compliant host equipment.
Radiated Energy
DIP 2
DIP 3
DIP 4
Note: This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against
OFF
X
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
ON
X
with this instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will
ON
X
be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void
OFF
X
your right to operate this equipment.
OFF
X
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
Emissions
Warning: In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Immunity
Electrical Safety
MDI-X Mode
Signal
RX+
RX-
TX+
TX-
4
U.S. Federal Communications Commission
Industry Canada
FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
EN55024
UL60950 (
UL
), EN60950 (TUV), CSA22.2 No. 950
c
us
Copyright © 2008 Allied Telesis, Inc. All rights reserved.
5
6