Dell PowerEdge M820 Systems 기술 매뉴얼 - 페이지 28

{카테고리_이름} Dell PowerEdge M820 Systems에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge M820 Systems 46 페이지. Dell poweredge blade servers getting started guide
Dell PowerEdge M820 Systems에 대해서도 마찬가지입니다: 정보 업데이트 (38 페이지), 릴리스 정보 (27 페이지), 사용자 설명서 (23 페이지), 중요 정보 매뉴얼 (35 페이지), 업데이트 매뉴얼 (32 페이지), 업데이트 매뉴얼 (28 페이지), 사용자 설명서 (26 페이지), 사용자 설명서 (22 페이지), 시작하기 매뉴얼 (12 페이지), 소유자 매뉴얼 (3 페이지), 포트폴리오 매뉴얼 (27 페이지), 시작하기 매뉴얼 (14 페이지), 시작하기 매뉴얼 (12 페이지), 기술 매뉴얼 (47 페이지)

Dell PowerEdge M820 Systems 기술 매뉴얼
Feature
Active power management
Fresh Air cooling
Rack infrastructure
Find additional information at
The M1000e chassis enclosure provides power and cooling for the M820 blade server. For
information on the M1000e power supply units, see the
Dell.com.
Optimized thermal management keeps fan speeds in the PowerEdge M820 as low as possible,
contributing to quiet operation and ensuring proper component cooling.
The thermal design of the PowerEdge M820 reflects the following:
Comprehensive thermal management: The PowerEdge M820 dynamically controls system
cooling fan speed, based on responses from critical sensors that monitor the temperature of
several components, including:
Processors
-
DIMMs
-
System inlet ambient
-
Mezzanine card
-
Network daughter card (NDC)
-
PowerEdge M820 Technical Guide
28
Description
Intel Node Manager is an embedded technology that provides individual
server-level power reporting and power limiting functionality. Dell offers a
complete power management solution comprised of Intel Node Manager
accessed through Dell iDRAC7 Enterprise and OpenManage Power Center
that allows policy-based management of power and thermals at the
individual server, rack and data center level.
Hot spare reduces power consumption of redundant power supplies.
Thermal control of fan speed optimizes the thermal settings for your
environment to reduce fan consumption and lower system power
consumption.
Idle power enables Dell servers to run as efficiently when idle as when at full
workload.
With the thermal design and reliability of Dell products, you can have the
capability to operate at excursion-based temperatures. This solution is
comprised of servers, networking, storage, and infrastructure that run
beyond the industry standard of 35°C (95°F) without impacting your
availability model. Find additional information at Dell.com/FreshAir.
Dell offers some of the industry's highest-efficiency power infrastructure
solutions, including:
Power distribution units
Uninterruptible power supplies
Energy Smart containment rack enclosures
Find additional information at
power-and-cooling-technologies-components-rack-infrastructure.aspx.
Dell.com/PowerAndCooling
(PDUs)
(UPSs)
http://content.dell.com/us/en/enterprise/
and Power.com/PowerCenter.
PowerEdge M1000e Technical Guide
on