Dell R1-2401 시작하기 매뉴얼 - 페이지 16

{카테고리_이름} Dell R1-2401에 대한 시작하기 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell R1-2401 20 페이지. Poweredge vrtx switch modules
Dell R1-2401에 대해서도 마찬가지입니다: 시작하기 매뉴얼 (30 페이지)

Dell R1-2401 시작하기 매뉴얼
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Dell
Table 4-1 describes the major switch defaults:
Table 4-1. Major System Defaults
Feature
SNMP
Login and Authentication
Authentication Servers
Logging
System Time
DHCP
Ports
Multicast
IGMP Snooping
MLD Snooping
Spanning Tree
VLANs
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 1 / 1 6 / 1 4 - F O R P R O O F O N LY
16
Initial Configuration of the Switch
Plasma\GSG\Plasma_UGHW&InitialConfiguration.fm
Defaults
Enabled.
SNMP version: V3.
SNMP Local Engine ID: 0000000001.
SNMP Notifications: Enabled.
Telnet authentication login is from the local user
data base.
HTTP authentication login is from the local data
base.
HTTPS authentication login is from the local
data base.
No RADIUS server is defined.
No TACACS server is defined.
No SYSLOG server is defined.
SNTP is supported.
DHCP server is disabled.
DHCP auto configuration is enabled.
24 GE regular ports (for
20 10G ports plus 2 GE regular ports (for
10Gb
Full duplex is enabled.
Negotiation is enabled.
Flow control is Off.
No LAGs are defined.
Multicast filtering is disabled.
Disabled
Disabled
Enabled
Default VLAN is enabled.
Default VLAN ID is 1.
VRTX 1Gb
).
).
VRTX