Dell S4128F-ON Series 설치 매뉴얼
Figure 7. S4100-ON Series PSU-side LEDs
1
Fan LED
3
PSU LED
Table 3. S4100–ON Series LED behavior
LED
System Status/Health LED
Power LED
Master LED
FAN LED
PSU LED
Locator LED/System Beacon
2
Link LED
4
Activity LED
Description
Solid green—Normal operation
Blinking green—Booting
Solid yellow—Critical system error
Blinking yellow—Noncritical system error, fan failure, or power
supply failure
Off—No power
Solid green—Normal operation
Solid yellow—POST is in process
Blinking yellow—Power Supply failure
Off—Switch is in Stacking Slave mode
Solid green—Switch is in Stacking Master or Standalone mode
Off—No power
Solid green—Normal operation; fan powered and running at the
expected RPM
Solid yellow—Fan failed—including incompatible airflow
direction when you insert the PSU or fan trays with differing
airflows
Off—No power
Solid green—Normal operation
Solid yellow—Power supply critical event causing a shutdown.
Blinking yellow—PSU warning event; power continues to
operate
Blinking green, 1.0 Hz—Standby mode
Blinking green, 0.5 Hz—Ac power cord unplugged
Off—Locator function is disabled
S4100–ON Series switch
11