Dell S4148F-ON Series 설치 매뉴얼 - 페이지 36
{카테고리_이름} Dell S4148F-ON Series에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell S4148F-ON Series 48 페이지.
Dell S4148F-ON Series에 대해서도 마찬가지입니다: 설치 매뉴얼 (47 페이지)
Fan LEDs
•
Solid green—fan function is normal.
•
Flashing yellow (amber)—there is a fan fault.
•
Off—fan is off.
Fan module installation
The fan modules in the S4100–ON Series (S4128F-ON, S4148F-ON, and S4148FE-ON) switch are field replaceable.
When looking at your switch, Slot 1 is on the left side of the switch and Slot 4 is on the right side of the switch.
CAUTION:
DO NOT mix airflow directions. All fans must use the same airflow direction—reverse or normal. If you mix the airflow
direction, to avoid overheating the switch, correct the mixed airflow.
1
Take the fan module out of the shipping box.
2
Slide the module into the bay.
Figure 21. S4100–ON Series fan modules installation
1
Fan unit
Fan module replacement
To request a hardware replacement, see
CAUTION:
Complete the following steps within one minute or the switch temperature could rise above safe thresholds and the
switch could shut down:
1
Slide the fan module out of the bay.
2
Slide the replacement module into the bay.
36
Fans
Dell EMC
support.