NOTE: Dell Networking recommends using one person to hold the S4810–ON chassis in place
while another person attaches the brackets to the posts.
Attach the bracket "ears" to the rack or cabinet posts using the two screws for each bracket. Ensure
the screws are tightened firmly.
Figure 5. Installing the System into a Two-Post Rack or Cabinet
1.
PSU1
3.
Rack Mounting Ears
Attaching the Mounting Brackets into a Four-Post Rack or Cabinet
The S4810–ON ships with mounting brackets (rack ears) and the required screws for a two-post rack or
cabinet installation.
To install the S4810–ON in a four-post rack or cabinet, you must order additional brackets separately.
Use the brackets included with the S4810–ON on the I/O side of system and use the brackets you
ordered separately on the PSU side of the system.
Unlike the two-post installation, the four-post installation requires attaching brackets to the rack prior to
installing the system.
To attach the brackets to the rack or cabinet, follow these steps.
1.
Ensure that there is adequate clearance surrounding the rack or within the cabinet to permit access
and airflow.
2.
Take the brackets and screws out of their packaging.
Install the S4810–ON
2.
PSU2
4.
Rack or Cabinet Post
17