Dell SwitchX M4001T 사용자 설명서 - 페이지 13
{카테고리_이름} Dell SwitchX M4001T에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell SwitchX M4001T 27 페이지. Infiniband blade switch i/o module for poweredge m-series
InfiniBand Blade Switch I/O Module for PowerEdge M-Series
2.2
Mechanical Installation
These switches are hot pluggable. It is not necessary to power down the Dell Chassis to install a
new switch or to replace an old switch with a new one.
M4001[F,T, Q] blades are not allowed in the Fabric A slots.
The switch can only be placed in channel slots B1, C1, C2 or B2.
2.2.1 Removing an Old Switch From the Chassis
1.
Remove any locking cables or screws that secure the old switch into the chassis.
2.
Disconnect all of the InfiniBand cables from the front of the switch to be removed.
3.
Unlock the switch from the chassis by pushing the red latch release button.
4.
Pull the locking arm down to a position perpendicular to the front of the chassis.
5.
Pull the switch out of the chassis using the locking arm.
Figure 5: Rear View of the Dell PowerEdge M1000e Chassis
A1 B1 C1
C2 B2 A2
Channel 1 slots
Channel 2 slots
Latch Release Buttons
Locking Arms
Mellanox Technologies
Rev 1.2
13