EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS
Please follow the gas requirements listed below:
Inlet Gas Pressure 7" W.C. for Natural Gas - 10"W.C. for LP gas
Manifold Pressure: The amounts listed below are set at the factory.
Natural Gas Manifold pressure
90-PAGW
110-PAGW
130-PAGW
160-PAGW
LP Gas Manifold pressure
90-PAGW
110-PAGW
130-PAGW
160-PAGW
The inlet and manifold (outlet) pressure taps are located at the Gas Control Valve. This
part is in the burner controls box and attached to the oven support stand.
GAS PRESSURE
4" W.C.
4" W.C.
4.5" W.C.
4.5" W.C.
7" W.C.
7" W.C.
7" W.C.
7" W.C.