ALLIGATOR sens.it RetroFIT-kit 2.0 운영 매뉴얼 - 페이지 14
{카테고리_이름} ALLIGATOR sens.it RetroFIT-kit 2.0에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ALLIGATOR sens.it RetroFIT-kit 2.0 18 페이지. Pressure monitoring system
Step 3: Minimum pressure (select limit
16
Please use the pressures recommended by the vehicle manufacturer for the setpoint for
the adjustment of limit values. This is usually provided on the inside of the fuel door, on the
driver door or on the B-column. If you cannot find it there, please refer to your owner's
manual for help.
Pressure setpoint: Tyre pressure recommended by the manufacturer (Figure 16)
Limit value - 20%: Based on the European Directive ECE-R64, we recommend adjusting
The limit value must always be less than the pressure setpoint so that the system issues a
warning.
Pressure setpoint
(bar)
1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5
Limit value - -10%
1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2
Limit value - -20%
1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.2 2.3 2.4 2.5 2.6 2.6 2.7 2.8
Pressure setpoint
(psi)
28
Limit value - -10%
25
Limit value - -20%
22
Step 4: Limit value (alarm) adjustment
- Press and hold Bt1 to enter the settings.
- Press Bt1 repeatedly until LO appears in the top right of the display.
- First the limit values of the front axle that were specified in Step 3 are adjusted. Then the
process is carried out for the rear axle.
the limit value so that an alarm message is issued with a pressure loss
of 20% or a minimum pressure of 1.5 bar at the latest.
29
30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
26
27 28 29 30 31 32 32 33 34 35 36 37 38 39 40
23
24 25 26 26 27 28 29 30 30 31 32 33 34 34 35
value)
14