360 Vision Affiniti Thermal IP 설치 및 구성 매뉴얼 - 페이지 11
{카테고리_이름} 360 Vision Affiniti Thermal IP에 대한 설치 및 구성 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. 360 Vision Affiniti Thermal IP 20 페이지.
Affiniti Thermal IP Install Manual V2.1.17.3
Page 11
5.4 Advanced Video/Stream
Stream 1
IP Ratio/GOP value
25 (default)
E.g. 1 'i-frame' every 25th image.
(type in a number)
RTP Block Size
15000 (default)
Range 0 (Ethernet MTU), 1440 to 65500
Force I Frame
Yes
Forces camera to send an 'i-frame' when OK is selected.
(Tick box to select Yes)
No (default)
Range 0 to 99
I Frame Size
99
(average frame size x value/10 = i frame size)
QP Value
Init
-1 (default)
(Quantization
Min
8 (default)
Parameter).
Max
44 (default)
For engineers use only.
Auto (default)
DO NOT ADJUST.
Encode Preset
Custom
Always use the default settings.
SVC
Packet Size
100 (default)
(% of Frame Data Value)
OK to program the new settings into the Affiniti Thermal IP.
Cancel to abandon the changes to the advanced video settings.
Back to return to the video settings.
© 360 Vision Technology Ltd.