Miele PW 6088 EL LP 설치 계획 - 페이지 7

{카테고리_이름} Miele PW 6088 EL LP에 대한 설치 계획을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele PW 6088 EL LP 8 페이지.

Technical datasheet
Washer-extractor:
Heating:
Legend:

Optional extras:

US 6008 (US = plinth with drawer)
Miele plinth
Height
UM
Width
Depth
Quality and density of concrete must comply with load. Con-
Concrete plinth
crete plinth must be firmly secured to floor!
BS
Recommended height
Minimum height
Recommended width
Recommended depth
Machine connections:
Electrical
connection
Technical datasheet: PW 6088 EL LP
Date: 01.04.2014
Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
1. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Supply lead cross-section
Length of supply lead
Supply lead without plug (supplied)
Electrical connection must comply with national regula-
tions.
A wall socket or mains isolator must be easily accessible
after installation.
Reinstallation of the supply point, changes to the equip-
ment or checks on the protective conductor, including de-
termination of correct fuse rating, should only be per-
formed by a properly trained electrician.
PW 6088 LP
Electric (EL)
en - AU
mm
320
mm
692
mm
685
mm
300
mm
70
≥700
mm
≥700
mm
V
1N AC 230
Hz
50
kW
5.5
A
1 × 25
mm²
3 × 2.5
mm
2170
Page: 7