Miele PW 6101 프로그래밍 지침 매뉴얼 - 페이지 21
{카테고리_이름} Miele PW 6101에 대한 프로그래밍 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele PW 6101 48 페이지. Profitronic m innovation m
Miele PW 6101에 대해서도 마찬가지입니다: 사용 설명서 (44 페이지), 사용 설명서 (46 페이지), 프로그래밍 지침 매뉴얼 (48 페이지)
2. Programme stop 1
This is used to stop a programme.
Selection choice:
– No
The programme does not stop.
– Permanent
The programme always stops at the position
programmed.
– Starch stop
– Without spin
If "Starch stop" or "Without spin" are selected
the programme will only stop at the position
programmed if the respective button is
pressed at this point.
– Spin and Starch stop
If "Spin and Starch stop" is selected the
programme will only stop at the position
programmed if the respective buttons are
pressed at this point.
3. Programme stop signal 1
This is used to set the "Programme stop"
output (for signal transmitter).
Selection choice:
– No
The "Programme stop" output is not
controlled during a programme stop.
– Yes
The "Programme stop" output is controlled
during a programme stop.
M.-Nr. 06 533 430
4. Heating
Is used to control the heating. It can, for
example, be used for hot water rinsing.
Selection choice:
– Yes
The heaters are controlled in the normal way
to reach the selected temperature.
– No
The heating is not switched on. The
temperature selected is controlled via the
water intake valves only. The Thermo stop
setting has to then be set to "No". The
required temperature field in the display
remains empty before and after the start of
the programme.
5. Free temperature selection
This option allows you to make a change to
the temperature before starting a
programme.
Selection choice:
– No
The temperature programmed into the block
is always used.
– Yes
The temperature set before the start of the
programme for the 1st main wash is
allocated to all programme blocks if "Free
temperature selection" has been set to "Yes"
for all the blocks and as long as the
programmed temperature is not smaller.
Programming