Optional modules
Priming the dispensing pumps
Use the calibration to get liquid detergent to the
pumphead. Once calibration is complete run an
empty program to get detergent to the machine
before actually washing a load of laundry in the
machine.
Dispensing calibration
The dispensing calibration is used to calculate the
flow rate of each dispensing pump.
For direct access to the dispensing calibration when
the machine is turned off:
^ Press and hold the 2
nd
^ Turn the machine on at the mains and release the
control key.
Dispensing calibration ~ Main menu
Dispensing pump 1
Dispensing pump 2
Selections: Dispensing pump 1 to 13
After selecting a dispensing pump the display shows:
Dispensing calibration ~ Dispensing pump 1
V: 100ml
t: 0s
The dispensing amount can be adjusted in 1 ml
increments from 0 to 999 ml.
^ Press the 0/1 control key, the dispensing hose fills.
Press the 0/1 button again to stop.
^ Point the hose of the dispensing pump to be deter-
mined, in a measuring cup. Hold the cup high
enough so the liquid has to be pumped rather than
flowing out.
,
Avoid skin and eye contact, wear protective
clothing.
^ Press A to get back to the main menu.
Dispensing calibration ~ Main menu
Dispensing pump 1
Dispensing pump 2
^ Select the dispensing pump.
Dispensing calibration ~ Dispensing pump 1
V: 100ml
t: 0s
24
control key from the left.
e
A
No
S
A
0/1
e
A
No
S
A
0/1
^ The dispensing can be manually stopped by pres-
sing the 0/1 button or it will stop automatically after
60 seconds.
^ Measure the pumped amount in the measuring
cup.
Dispensing calibration ~ Dispensing pump 1
V: 100ml
t: 30s
^ Enter the measured amount in the "V:" field. The
flow rate P: in milliliter per minute is calculated by
the control.
^ Press S "Save" to allocate the measured values to
the dispensing pump.
^ Reconnect the hose.
Maintenance of the dispensing system
Rinse the dispensing system with hot water every 2
weeks, or before shutting down the dispenser pumps
for any length of time, to prevent the system from
clogging.
^ Rinse out the suction pipes with water.
^ Place the suction pipes in a container with warm
water, 104 - 122°F (40 - 50°C).
^ Select each pump by using the dispensing cali-
bration.
^ Turn on each pump until the dispensing system is
rinsed.
^ Check the connection points, hoses and washers
for leaks.
P: 200.0 ml/min
S
A
0/1