Notes for the installer
Liquid dispensers
Cold water
Hot water

Plumbing

Connection must be made to the water
supply via a stopcock which conforms to
local and national regulations. This work
must be carried out by an authorised person
in accordance with local and national
regulations.
Water inlet / drainage
See the enclosed installation diagram for
instructions on how to connect the machine
to the water inlet and to the drainage
system.
To ensure trouble free operation of the
machine the flow pressure must be at least
100 kPa (1 bar) and not exceed 1000 kPa (10
bar).
The inlet pressure tested hoses supplied
with the machine must be used for
connection to the water supply.
42
Hard water
Cold water
If replacing an inlet hose only use a hose
tested to at least 7000 kPa (70 bar)
pressure, and for a water temperature of at
least 90 °C. This also applies to all fittings.
Miele original parts fulfil these requirements.
Water taken into the machine must not
exceed a temperature of 70°C.
Cold water supply
1"
See the enclosed installation diagram for
instructions on how to connect the machine
to the water inlet and to the drainage
system.
3/4"