Notes for the installer
Drainage
- Machines with a Drain Pump
The machine drains via a drain pump with a
delivery head of 1 metre. The 1.5 m long
drain hose must not be kinked as this
restricts drainage. The swivel elbow at the
end of the hose can be turned or detached.
Drainage possibilities:
^ Direct into a sink: (for the drain pump
version). Hook the hose over the edge and
secure.
Make sure the water can flow away freely
to avoid flooding and to prevent water from
being sucked back into the machine.
^ Connection to a standpipe.
^ Connection to a plastic drain pipe with a
rubber nipple. There is no need for a
non-return valve.
^ Drainage via a floor drain (gully).
- Machines with a Dump Valve
The machine empties through a motor
controlled dump valve. A DN 50 angle
connector can be used to make connection
to an on-site drainage system, (sink box with
odour trap).
Coin mechanism unit
The washer-extractor can be fitted with a
coin unit.
It can also be connected to an existing coin
unit. The correct connection cable is
required for this. For the C 4030 / 4031,
C 4050 / 4051 and C 4065 / 4070 using
timed operation an AD 3 adapter is required.
The machine has to be reprogrammed for
this connection. This must only be done by a
Miele authorised service engineer.
The coin unit and connection cable are
available at extra cost from the Miele Spare
Parts Department, or from Miele specialist
dealers.
32

Electrical connection

All electrical work must be carried out by a
suitably competent person in compliance
with current national and local regulations.
Please take note of the Installation diagram
and the Wiring diagram. They are important
for electrical connection.
This machine is constructed in accordance
with IEC 60204-1:2005 and complies with
the following electrical standard: IEC 335.
The minimum suds level required for
activating the heating is given in mm column
of water: W 6073 45 mm column of water
The voltage and frequency are given on the
data plate. The machine must only be
connected if these match the mains supply.
Variants: 3N AC 380-415 V 50 Hz
3
AC 220-240 V 50 Hz
3
AC 440
1
AC 220-240 V 50 Hz
The motor is fitted with an overload
protection switch.
For extra safety it is advisable to install
suitable residual current device.
Nominal rated load and fuse rating are given
on the data plate. Ensure that these are
compatible with the electricity supply.
WARNING
THIS APPLIANCE MUST BE EARTHED
Connection should be made via a suitable
isolator with an on-off switch located near
the machine which can be used as an
emergency off switch. It should be coloured
red and yellow for easy identification.
When installation and connection have
been completed all removable outer
panels must be re-fitted before the
machine is operated.
V 60 Hz
M.-Nr. 06 006 842