Total connected load*
DA 2250, DA 2270. . . . . . . . . . . . 300 W
DA 2210. . . . . . . . . . . . . . . . . . . . 780 W
– Fan motor
DA 2250, DA 2270 . . . . . . . . . . 200 W
DA 2210 . . . . . . . . . . . . . . . 2 x 290 W
– Hob lighting
DA 2250, DA 2270 . . . . . . . . 2 x 50 W
DA 2210 . . . . . . . . . . . . . . . . 4 x 50 W
Voltage . . . . . . . . . . . . . . . . . AC 230 V
Frequency . . . . . . . . . . . . . . . . . . 50 Hz
Fuse rating GB . . . . . . . . . . . . . . . . . 5 A
AUS, NZ:
Plug rating . . . . . . . . . . . . . . . . . . . 10 A
Test marks . . . . . . . . . . Electrical safety
. . . . . . . . . . . . . . . . . . . . . . C-Tick Mark
Electrically suppressed
according to AS/NZS 1044
Electrical cable length . . . . . . . . . 1.5 m
Weight
DA 2250 . . . . . . . . . . . . . . . . . . . . . 8 kg
DA 2250 EXT . . . . . . . . . . . . . . . . 5.5 kg
DA 2270. . . . . . . . . . . . . . . . . . . . 9.5 kg
DA 2270 EXT . . . . . . . . . . . . . . . . . 7 kg
DA 2210 . . . . . . . . . . . . . . . . . . . . 16 kg
Special accessory for recirculation
mode:
– Conversion kit DUU 151
2 kits are required for the DA 2210
– Miele charcoal filter pack DKF 15-1
(each pack contains 2 filters)
2 packs are required for the DA
2210
Fan performance*
Extraction power according to EN 61591
DA 2250, DA 2270:
Extraction system C 150 mm
Level I . . . . . . . . . . . . . . . . . . . 200 m
Level II. . . . . . . . . . . . . . . . . . . 300 m
Level III . . . . . . . . . . . . . . . . . . 400 m
Level IV Intensive Setting . . . . 640 m
Recirculation with charcoal filter:
Level I . . . . . . . . . . . . . . . . . . . 140 m
Level II. . . . . . . . . . . . . . . . . . . 240 m
Level III . . . . . . . . . . . . . . . . . . 360 m
Level IV Intensive Setting . . . . 550 m
Unrestricted. . . . . . . . . . . . . . . 690 m
DA 2210:
Extraction system 2 x C 150 mm
Level I . . . . . . . . . . . . . . . . . . . 650 m
Level II. . . . . . . . . . . . . . . . . . . 950 m
Level III . . . . . . . . . . . . . . . . . 1250 m
Level IV Intensive Setting . . . 1850 m
Recirculation with charcoal filter:
Level I . . . . . . . . . . . . . . . . . . . 600 m
Level II. . . . . . . . . . . . . . . . . . . 900 m
Level III . . . . . . . . . . . . . . . . . 1200 m
Level IV Intensive Setting . . . 1550 m
Unrestricted. . . . . . . . . . . . . . 2000 m
* For EXT models,
the rated load and extraction power will
depend on the type of external motor
fitted.
Length of connection cable to external
motor. . . . . . . . . . . . . . . . . . . . . . . 1.9 m
Technical data
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
37