Do not install this exhaust hood over
cooktops burning solid fuel.
When installing the hood, adhere to
the following minimum distance (S)
between the top of a Miele cooking
surface and the bottom of the hood:
- 22" (55 cm) above electric cooktops
- 26" (65 cm) above gas cooktops
- 26" (65 cm) above an open grill
For non-Miele appliances, maintain
the safety distances recommended
by the cooktop manufacturer in their
installation instructions.
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
Observe local building codes.
See "Important Safety Instructions"
for further information.
26" (65 cm) is recommended for all
installations to allow for optimum work
space under the hood.
CAUTION:
During the installation process,
please be careful of sharp edges
that can cause harm.
^ Mark a line on the ceiling going from
the rear of the cooktop towards the
front and centered over the cooktop.
^ Cut a 7
1
/
" (190 mm) hole in the
2
ceiling for the exhaust duct to pass
through. The exhaust connection has
a 6" (150 mm) diameter.

Installation

27