Appliance dimensions

DA 270-4, DA 270-4 EXT
DA 270-4 U
26
1) Cut-out for feeding through the
exhaust ducting, the mains cable and,
with ... EXT models, the connection
cable to the external motor
In recirculation mode, only the mains
cable is required.
Exhaust connection C 150 mm (not
needed for recirculation mode)
Safety distance between hob and
cooker hood
The minimum safety distances
between the top of a cooker or hob
and the bottom of the cooker hood
are as follows, unless a greater
distance is specified by the
manufacturer of your cooking
appliance:
550 mm
above electric hobs and
cookers
650 mm
above gas hobs and
cookers
650 mm
above an open grill or
deep fat fryer.
See "Warning and Safety" instructions
for further information.
– A distance of 650 mm above the hob
may be preferable to give more