Miele DA 3460 운영 및 설치 매뉴얼 - 페이지 35
{카테고리_이름} Miele DA 3460에 대한 운영 및 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele DA 3460 40 페이지. Ventilation system
Miele DA 3460에 대해서도 마찬가지입니다: 운영 및 설치 매뉴얼 (40 페이지), 작동 및 설치 지침 (40 페이지), 설치 지침 매뉴얼 (24 페이지)
– If the exhaust is ducted into an
inactive flue, the air must be expelled
parallel to the flow direction of the
flue.
Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
Condensate trap
optional accessory
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and 6"
(150 mm) in diameter.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.
Air extraction
35