Installation
Setting up for recirculation
mode
If site conditions are not suitable for the
cooker hood to be used with air
extraction, the appliance must be set
up for recirculation.
For this, conversion kit DUU 151
(available from your Miele dealer or the
Miele Spare Parts Dept.) is required.
You will also need a charcoal filter (see
"Technical data").
^ Fit the conversion kit as described in
the installation instructions supplied
with the kit.
32
^ Make sure that the slats in the
exhaust grille point towards the
centre of the room and not towards a
wall or the ceiling.
A non-return flap is not used in
recirculation mode.
^ Fit the charcoal filter (see "Cleaning
and care").
Electrical connection
Refer to the notes in "Electrical
connection" and "Warning and
Safety instructions" before
connecting to the electricity supply.
^ For appliances connected to an
external motor (EXT models):
Connect the cooker hood to the
external motor using the connecting
cable and the 6-pole plug connector.
^ Separate fitting instructions are
supplied with the external motor.