Connection for air extraction
 If the exhaust ducting is to run
through rooms, ceiling space etc.
there may be great variations in
temperature between the different
areas. The problem of condensation
will need to be addressed. The
exhaust ducting will need to be
suitably insulated.
Miele will not accept warranty claims
for any functional defects or damage
caused by inadequate ducting.

Condensate trap

In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is also installed to
collect and evaporate any condensate
which may occur.
Condensate traps are available for
125 mm or 150 mm ducting.
 When installing a condensate trap,
ensure that it is positioned vertically
and, if possible, directly above the
exhaust socket.
The arrow on the housing indicates
the direction of airflow.
42
The condensate trap is integrated in
rangehoods which are designed to be
connected to an external motor (EXT/
EXTA models).

Silencer

To achieve even further reductions in
noise levels, a special silencer (optional
accessory) can be fitted in the ducting
system.
Air extraction mode
The silencer not only reduces noise
from the motor outside the house, but
also sounds from outside (e.g. traffic
noise). For this reason, the silencer
must be positioned as close as possible
to the ducting exit .