Miele DA 429-4 EXT 작동 및 설치 지침 - 페이지 38

{카테고리_이름} Miele DA 429-4 EXT에 대한 작동 및 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele DA 429-4 EXT 40 페이지. Cooker
Miele DA 429-4 EXT에 대해서도 마찬가지입니다: 운영 및 설치 매뉴얼 (40 페이지), 운영 및 설치 매뉴얼 (40 페이지)

Miele DA 429-4 EXT 작동 및 설치 지침

Technical data

Total connected load*
DA 428-4 . . . . . . . . . . . . . . . . . . . 240 W
DA 429-4 . . . . . . . . . . . . . . . . . . . 260 W
Fan motor* . . . . . . . . . . . . . . . . . . 200 W
Hob lighting
DA 428-4 . . . . . . . . . . . . . . . . . 2 x 20 W
DA 429-4 . . . . . . . . . . . . . . . . . 3 x 20 W
Voltage . . . . . . . . . . . . . . . . . . . . 230 V
Frequency . . . . . . . . . . . . . . . . . . 50 Hz
Fuse rating GB . . . . . . . . . . . . . . . . . 3 A
AUS, NZ:
Plug rating . . . . . . . . . . . . . . . . . . . 10 A
Test marks . . . . . . . . . . Electrical safety
. . . . . . . . . . . . . . . . . . . . . . C-Tick Mark
Electrically suppressed
according to AS/NZS 1044
Electrical cable length . . . . . . . . . 1.5 m
Weight
DA 428-4. . . . . . . . . . . . . . . . . . . . 18 kg
DA 428-4 EXT . . . . . . . . . . . . . . . . 15 kg
DA 429-4. . . . . . . . . . . . . . . . . . . . 19 kg
DA 429-4 EXT . . . . . . . . . . . . . . . . 16 kg
38
Fan performance*
Extraction power according to
EN 61591
Extraction system C 150 mm:
Level I . . . . . . . . . . . . . . . . . . . 200 m
Level II. . . . . . . . . . . . . . . . . . . 300 m
Level III . . . . . . . . . . . . . . . . . . 400 m
Level IV Intensive Setting . . . . 640 m
Extraction system C 125 mm:
Level I . . . . . . . . . . . . . . . . . . . 180 m
Level II. . . . . . . . . . . . . . . . . . . 280 m
Level III . . . . . . . . . . . . . . . . . . 380 m
Level IV Intensive Setting . . . . 580 m
Recirculation with charcoal filter:
Level I . . . . . . . . . . . . . . . . . . . 150 m
Level II. . . . . . . . . . . . . . . . . . . 210 m
Level III . . . . . . . . . . . . . . . . . . 330 m
Level IV Intensive Setting . . . . 490 m
Special accessory for recirculation
mode:
– Conversion kit DUW 20
– Miele charcoal filter DKF 12-1
* For EXT models, the connected load
and extraction power will depend on
the type of external motor fitted.
EXT models:
Length of connection cable to external
motor. . . . . . . . . . . . . . . . . . . . . . . 1.9 m