The cooker hood works with
. . . air extraction:
The air is drawn in and cleaned by the
grease filters and directed outside.
If the on-site ventilation system does
not have a non-return flap, the
non-return flap supplied with the
appliance must be fitted in the exhaust
socket in the motor unit.
Having a non-return flap fitted in the
ducting ensures that air, once ducted
to the outside, cannot get back into the
room again.
The flap is closed when the cooker
hood is switched off.
When the cooker hood is switched on,
the non-return flap opens for the
cooking vapours to be blown directly
outside.

Modes of operation

. . . air recirculation:
(this requires an optional conversion kit
and charcoal filter: see "Technical
Data")
The air is drawn in and cleaned first by
the grease filters and then by a
charcoal filter. The cleaned air is then
recirculated back into the kitchen
through grilles in the top of the cooker
hood telescopic extension piece.
Before using the cooker hood in
recirculation mode, ensure that the
charcoal filter is in place. See
"Cleaning and care".
. . . an external motor:
(...EXT models only)
The ...EXT models are designed to be
connected to an external motor located
outside the room.
The external motor is connected to the
cooker hood by means of a control
cable, and is operated by the controls
on the cooker hood.