Allmatic INVERTER COMPACT 지침 - 페이지 15

{카테고리_이름} Allmatic INVERTER COMPACT에 대한 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Allmatic INVERTER COMPACT 20 페이지.

WARNING: the photocells and the safety edge are not monitored during this phase!
WARNING! during this phase the photocells and the coast are not monitored! Access the manual movement item of MENU B and confirm by pressing
the P2 key. Move the gate using the P1 and P3 keys. To exit the menu, press the P2 button or wait for 15 seconds.
7. LEARNING
Learning the run of the gate (Menu B - Final position). Learning the run allows to define the parameters of the run of the gate, such as the width of the
run at normal speed and at slowed speed. Check that the adjustment of the torque and the speed of the gate are set before carrying out the learning
phase. Check that the gate is closed before starting the learning phase.
End Position
OK
MENU' B, end position:
allows you to start learning the
races, starting from the opening
movement. Access the item
LEARN OP
EXIT
The gate continues at reduced
speed until the opening limit
switch is reached. When the
limit switch is reached, it auto-
matically restarts in closing
7.1 Learning the partial opening phase (Menu B – Ped. Position). Make sure that the electric limit switches are assembled and
properly adjusted.
Learning the pedestrian run allows to define the position of partial opening that allows the pedestrians accessing (PED command)
Check that the adjustment of the torque and the speed of the gate are set before carrying out the learning phase. Check that the gate is closed before
starting the learning phase.
Enter the parameter Ped. Position of MENU B and confirm by pressing key P2. Start moving the gate by pressing and releasing key P1 (START) or a
Step-by-Step key. When the gate reaches the position of pedestrian opening, then push key P1 (START) or a step-by-step key
The gate moves again in closing. When the gate hits the limit in closing, then the programming is terminated. Exit the menu by scrolling the entries
until you find EXIT
7.2 Adjustment of the speed and the torque (Menu B - Speed and torque)
The entries of menu B - Speed and torque - once the parameters themselves are entered allow to adjust the corresponding parameters from a
minimum up to a maximum value, according to the indications shown on the display. The versatility of the control board allows an infinity of possible
combinations: however it is recommended to adjust the settings by keeping into account the dimensions and weight of the gate. High speeds may be
dangerous, as well as high torques. Such regulations must be carried out only by professionals. It is recommended to check the correct functioning of
the automation after any regulation. It is highly recommended to learn the runs of the gate each time these parameters are changed.
8. ADVANCED FUNCTIONS
These are functions and/or functional modalities that can be activated by the user through the programming menu.
8.1 AUTOMATIC RECLOSURE
Timed closing of the gate from totally open position or pedestrian opening position. The "stop" command disables the automatic closing until a new
START
SLOW
LEARN OP
EXIT
Press and release the
START key (P1), the gate
will start to open.
LEARN CL
EXIT
When the gate has
reached the position where
you want to start the
slowing down phase, press
the RALL button (P1)
LEARN OP
SLOW
EXIT
When the gate has reached
the position where you want
to start the slowing down
phase, press the RALL button
(P1)
LEARN CL
EXIT
When the closing limit
switch is reached, the
learning is performed.
15 / 20