Electrical connection
All electrical work should only be under-
taken by a suitably qualified and com-
petent person in strict accordance with
national and local safety regulations.
The cooker hood is supplied for con-
nection to a 220-230 V single phase
50 Hz supply.
The data plate gives the necessary
data for connection. This is visible
when the grease filter has been
removed.
Connection should be made by a
double pole fused spur connection unit
and the On-Off switch should be easily
accessible after the appliance has
been built in.
When switched off there must be an all-
pole contact gap of 3 mm in the switch
(including switch, fuses and relays ac-
cording to EN 60 335).
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA (in accordance
with DIN VDE 0664).
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue
= neutral
Brown
= live.