Miele Imperial DWW 750 운영 및 설치 매뉴얼 - 페이지 13
{카테고리_이름} Miele Imperial DWW 750에 대한 운영 및 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele Imperial DWW 750 40 페이지.
An indicator lamp shows when the
grease filter needs to be cleaned. The
operating hours counter for the grease
filter is set at the factory for a certain
number of hours but these can be
changed if required.
The operating hours counter for the re-
circulation micro-filter is set at the fac-
tory for an unlimited number of hours
but these can be changed if required.
After this set time has elapsed, the indi-
cator lamp next to the grease filter /
micro-filter touch control glows. The
grease filter must then be cleaned or
the micro-filter replaced by a new one.
After the grease filter has been cleaned
and put back in place or the micro-filter
has been replaced by a new one, the fil-
ter operating hours counter must be re-
set.
– To do this press the grease filter /
micro-filter touch control and hold for
about 4 seconds.
The indicator lamp will go out.
To check the percentage of the time set
already used:
– Use the On/Off touch control to
switch the fan on.
– Press the grease filter / micro-filter
touch control.
One or several of the indicator lamps
between the
/ touch controls will
flash.
The number of flashing lamps indicates
the percentage of operating time set al-
ready used up.
1 lamp
= 25%
2 lamps = 50%
3 lamps = 75%
4 lamps = 100%
The number of operating hours used re-
mains in memory, even when the ap-
pliance is switched off or there is a
power cut.
13