Dimensional drawings

 In case of the presence of combustible material an additional minimum clear‐
ance of 6" (each side) is necessary. Ensure local codes are observed.
Position
1) The Platform must be ³/₄" (19.05 mm) thick.
It must include a cut-out of 5¹/₈" x 3¹/₈" (130 mm x 80 mm) (gas connection) at the rear right
and a cut-out of 4³/₄" x 1⁹/₁₆" (120 mm x 40 mm) (elctrical connection) at the rear left.
40
Dimension
13" (330 mm)
18" (457 mm)
7¹/₂" (190.5 mm)
10" (254 mm)
Description
Maximum depth of top cabinet
Minimum distance to bottom edge
of top cabinet
Distance top edge of worktop to
top edge of platform
Minimum distance to flammable
surfaces
1)
Platform