Miele KMR1136 G 설치 지침 - 페이지 4
{카테고리_이름} Miele KMR1136 G에 대한 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele KMR1136 G 21 페이지.
Dimensional drawings
In case of the presence of combustible material an additional minimum clear‐
ance of 6" (each side) is necessary. Ensure local codes are observed.
Position
1) The Platform must be ³/₄" (19.05 mm) thick.
It must include a cut-out of 5¹/₈" x 3¹/₈" (130 mm x 80 mm) (gas connection) at the rear right
and a cut-out of 4³/₄" x 1⁹/₁₆" (120 mm x 40 mm) (elctrical connection) at the rear left.
40
Dimension
13" (330 mm)
18" (457 mm)
7¹/₂" (190.5 mm)
10" (254 mm)
Description
Maximum depth of top cabinet
Minimum distance to bottom edge
of top cabinet
Distance top edge of worktop to
top edge of platform
Minimum distance to flammable
surfaces
1)
Platform